All products ship same day from our warehouse in Walnut, CA if ordered within the shipping cutoff times
Cisco SFP-H10GB-CU3M Compatible 10GBASE-CU SFP+ Passive Direct Attach Copper Cable 3 Meter, 30AWG
For high speed, short length connections, these Cisco compatible SFP-H10GB-CU3M SFP+ direct attach cables are designed as a cost-effective, low latency, low power alternative to fiber optic cables. Typically used in data centers in between rack networks / servers, these direct attach cables are fully hot-pluggable, will support speeds up to 10 Gigabit Ethernet, and are fully compliant with MSA (Multi-Source Agreement) standards.
The Leapmicro SFP-10G-3M is backed with a 2-year warranty for reliability and performance from PI Manufacturing.
Features
WARNING:
Cancer and Reproductive Harm
www.P65Warnings.ca.gov
(California law requires this warning to be provided to California customers)
Specifications | |
---|---|
Cable Jacket Type | PVC |
Impedance | 100 ohm |
Wire Gauge | 30AWG |
Number of Lanes | 1 - TX and 1 - RX |
Maximum Data Rate | 10Gbps |
Operating Temperature | 0 to 70°C |
Storage Temperature | -40 to 85°C |
Supply Voltage | 3.3V nominal |
Electrical Interface | 20-pin edge connector 20-pin edge connector |
Management Interface | Serial, I²C |
High Speed Characteristics | ||||||
---|---|---|---|---|---|---|
Parameter | Symbol | Min | Typ | Max | Units | Notes |
Differential Impedance | Zd | 90 | 100 | 110 | Ω | |
Differential Input Return Loss | SDDXX | <-12+2* SQRT (f) with f in GHz <-6.3+13*Log10/(f/5.5) with f in GHz | dB | 0.01~4.1GHz 4.1~11.1GHz | ||
Common Mode Output Return Loss | SCCXX | < -7+1.6*f with f in GHz | dB | 0.01~2.5GHz | ||
-3 | dB | 2.5~11.1GHz | ||||
Difference Waveform Distortion Penalty | dWDPc | 6.75 | dB | |||
VMA Loss | L | 4.4 | dB | |||
VMA Loss to Crosstalk Ratio | VCR | 32.5 | dB |
Regulatory Compliance | ||
---|---|---|
Feature | Test Method | Performance |
Electrostatic Discharge (ESD) to the Electrical Pins | MIL-STD-883C Method 3015.7 | Class 1 (>2000 Volts) |
Electromagnetic Interference (EMI) | FCC Class B CENELEC EN55022 Class B CISPR22 ITE Class B | Compliant with Standards |
RF Immunity (RFI) | IEC61000-4-3 | Typically shows no measurable effect from a 10V/m field swept from 80 to 1000MHz |
RoHS Compliance | RoHS Directive 2011/65/EU and its Amendment Directives 6/6 | RoHS 6/6 compliant |